12 DOCR 070366-B
The inverter can be operated in ambient temperatures between -13°F to 158°F (-25°C to +70°C).
The following diagram illustrates how the power of the inverter is derated depending on ambient
temperature.
The device should be installed in a well-ventilated, cool and dry location.
Figure 1: Solectria PVI 3800-7600TL inverter output power vs ambient temperature curve
2.5 Inverter DC input voltage range
Figure 2: Solectria PVI 3800TL DC input voltage range
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
30 °C 40 °C 50 °C 60 °C 70 °C 80 °C
100% Nom. output pwr
@ 200 V
100% Nom. output pwr
@ 380 V
Nom. output pwr
@ 500 V
Nominal Output Power
Figure 1 demonstrates typical
behavior for PVI 3800-7600TL
series inverters.
2.4 Ambient temperature
Notice: Start up voltage is 150 V
dc
; full power MPPT voltage is 200 V
dc
Komentáře k této Příručce