Strany 1 - GSI-3000,4600 Instruction

Photovoltaic Inverter (PV)GSI-3000,4600 Instruction and Operator's Manual

Strany 2 - GSI-3000,4600 Introduction

75.Installation5.1 Package Check ListItemGSI-3000,4600Wall Mounting BracketPlastic AnchorMounting Bracket ScrewRear Panel Support ScrewUser ManualMC4

Strany 3

85.2 Choosing Installation LocationWARNING!WARNING!◎Do not mount the inverter in areas where highly flammable materials are stored.◎Install the invert

Strany 4 - Burn Hazard:

95. . 2 2 Environment◎Install on a firm surface which is capable of withstanding at least 20KG of weight.optimal performance.which will result in pow

Strany 5 - Grid Type (4600VA)

3.Install rear panel support screws on the rear of the GSI.Rear panel support screw positionABC5.3.2 Installation Procedure1.Use the mounting bracket

Strany 6 - Figure 2-3

7.Use the mounting bracket screw to fix the side holes of the GSI onto the wall mounting bracket.6.Check the sides of the GSI for correct positioning.

Strany 7 - 1 2 3 4 5

DC input: Uses 2 sets of MC4 connectors.AC output: Uses Wieland Flange connector.5.4 Electrical Connections5.4.1 Connection RequirementsBefore wiring,

Strany 8

135.4.3 Wiring MethodAC connection:Inverter End1 L:2 N:3 PE:Wire End1231 L:Sealed Cable Connector2 N:3 PE:Required Stripping LengthN,L8mm30mm}1235.4.2

Strany 9 - GSI-3000

145.5 Power ON/OFFGSI-3000,4600 DC input limits:Wire EndDC Input (+)Required Stripping LengthDC Input (-)6mmModelGSI-3000GSI-4600Maximum Input Voltage

Strany 10

155.5.1 Power ON1.Inspect the DC switch in PV module distribution box, use a multimeter to measure if the input is within rated values (125~500V).2.I

Strany 11 - WARNING!

166.Operation6.1 LCD DisplayMenu StructureFirmware VersionMaster MCU:Vx.xxSlaver MCU:Vx.xxMain MenuDisplay modeSetting modeSystem Infowaiting?yesnoWai

Strany 12 - Air flow

GSI-3000,4600 Introductionand Operator's ManualTable of Contents...

Strany 13

1.PWR : The green LED ON indicates that input power is normal. The green LED OFF indicates the OFF state, and the inverter will not connect to the uti

Strany 14

186.4.2.3 PV DC input infoPV string InfoString AVp : xxxV Ip : xx.xAPp:xxxxWString BVp: xxxV Ip : xx.xAPp:xxxxWPV String Split into channels A and B:V

Strany 15 - Warning!

196.4.2. Operating Time56.4.2.6 Error CodeTime : Accumulated operating timeEnergy: Accumulated power generationRecord No : xx, Please refer to table

Strany 16

6.4.3.3 Time SettingTime13:47:59 (hh:mm:ss)12/25/2010 (mm/dd/yyyy)(hh:mm:ss) Hour: Minute: Second Setting:(mm:dd:yyyy) Month: Day: Year Setting:6.4.4

Strany 17

7.TroubleshootingWhen an unpredictable error occurs, MEAN WELL advises the user to check the error code and notify the local system installation vendo

Strany 18

228.1 Communication Connections8.2 Wiring MethodPlease use the included cables with other wateproof wiring material.CH1 Connection to PC1. Red: Positi

Strany 19 - Menu Structure

23 c. Model SelectChoose GSI-3000 or GSI-4600.9.2.2 In the Data Display tab, select Start Receive Data to receive data. ErrorCode: Displays current GS

Strany 20 - MEAN WELL

249.2. Power parameter Setting3a.Input Password (For utility employees to modify)Password : meanwellb.Cosψc.Power Limitd.GSI system settinge.Setting

Strany 21

25Note 1 GSI ID address: Through the RS-485 interface, a PC can monitor as many as :250 GSI at the same time.System Info Physical Address Definition(0

Strany 22 - 8 16 1810 14

26Input End Channel A Data Physical Address Definition(0x6500 ~ 0x65FF):0x6120 Output 1 power Factor command (read only) Integer 1100~900 (Lead 0.9~La

Strany 24

27Integer Integer Integer Integer Integer 0~3000~100000~10000~15 0~3000~30.0A0~10000W0~1000V0~15A 0~300.0Hz(Output 2)(Output 1)(Output 2)(Output 1)(Ou

Strany 25

280x6B030x6B040x6B050x6B060x6B070x6B080x6B090x6B0AEvelog1_DayEvelog1_HrEvelog1_MinEvelog1_SecEvelog2_CodeEvelog2_YearEvelog2_MonEvelog2_DayEvent log 2

Strany 26

290x6B190x6B1A0x6B1B0x6B1C0x6B1D0x6B1E0x6B1F0x6B210x6B200x6B22Evelog4_HrEvelog4_MinEvelog4_SecEvelog5_CodeEvelog5_YearEvelog5_MonEvelog5_DayEvelog5_Mi

Strany 27

N o . 2 8 , W u q u a n 3 r d R d ., W u g u D is t ., N e w Ta i p e i C i t y 2 4 8, Ta i w a n

Strany 28 - Corresponding

11.Safety Guidelines0.Notes on this Manual◎GSI is a grid-tied PV inver ter that conv erts direct cu rre nt (DC) electricity into ◎This is a transforme

Strany 29 - Output 1 Power limit

2Grid Type (4600VA)2 2 Block Diagram.2 Features.1‧True sine wave current output (THD<3%)‧High efficiency up to 96%‧IP65 design for indoor or outdo

Strany 30

3DC Current Injection (Typ.)AC ConnectionEfficiencyMax. Efficiency (Typ.)Euro Efficiency (Typ.)ProtectionDC Reverse PolarityOver TemperatureAC ShortOv

Strany 31

43 Appearance.3 1 Front View.3 Electrical and Communication Connections.2PW RFAULTEN TER U P DO WN E SCPWR :Power indicator, refer to chapter 6 for i

Strany 32

54.Functions4.1 escriptionBrief D4.2 Safety Features4.3 ControlThe GSI is a single phase grid-tied PV inverter, which is unlike to the stand-alone To

Strany 33

6DeratingGSI-4600GSI-3000AMBIENT TEMPERATURE ( )℃AMBIENT TEMPERATURE ( )℃Figure GSI-4600 Load vs. 4-2 Ambient Temperature CurveFigure GSI-3000 Load